SINCE 1889 Yamato Scientific Co.,Ltd.
Contact Us   Site Map JapaneseChinese
Products Support Corporate Profile Global Network Contact Us
HOMEProductsDrying OvenDP610P
*
Industrial & Laboratory Vacuum Drying Oven
DP610P
*

Vacuum pump linkage automatic sequence type which release the manual operation of a vacuum pump and a leak valve.
Don't have to worry about the incorrect operation, reverse flow of vacuum pump oil when power off.

Operating Temperature Range
+40 to 200 deg.C
Internal Capacity
216L

PDF Catalog
  • Automatic sequence operation of vacuum pump linkage is possible.
  • Saving space, high quality controller, individual overheating prevention and many others function.
  • Prevent the reverse flow of vacuum pump oil when power off.
  • There is no exhaust loss because of 1 inch solenoid vacuum valve.
  • Automatic/manual switch is set up.

Specifications
Model DP610P
Performance
System Vacuum drying by decompressed chamber direct heating
Operating temperature range +40 to 200 deg.C
Operating pressure range 101 to 0.1 kPa (760 to 1 Torr) at absolute pressure
Temp. adjustment accuracy ±1deg.C (at 200 deg.C)
Temp. Fluctuation ±1.5deg.C (at 200 deg.C)
Max. temp. reaching time Approx. 100 min.
Components
Interior material Stainless steel
Exterior material Cold rolled steel plate with baked-on melamine resin finish
Heating method Decompressed chamber direct heating
Heater Mica heater, 3.15 kW
Vacuum gauge Bourdon tube type, 0 to 0.1 MPa (Gauge pressure)
Observation window Tempered glass and polycarbonate resin plate
Controller
Temp. control method PID control by microprocessor
Operation function Fixed temperature operation, Auto-start operation, Auto-stop operation, program operation ( 99 steps, 99 patterns repeat operation)
Additional functions Calendar timer (max. 24 Hrs.), Integration time (max 65535 Hrs.), Time display, calibration offset, power discharge, CO2 discharge, heater consumption display, power failure stagnation mode, user configuration information
Heater circuit control Triac zero-cross control
Temp. sensor K-thermocouple (double sensor)
Safe Device
Safety countermeasures Self diagnosis functions(Sensor, Heater, Triac, automatic overheating prevention), Independent overheating prevention, Key lock function, Electric leakage breaker
Standard
Internal dimensions (W×D×Hmm) 600×600×600mm
External dimensions(W×D×Hmm) 820×819×1650mm
Internal capacity 216 liters
Shelf rest step number 4 steps
Shelf rest pitch 140mm
Exhaust port / Purge port NW25 flange / Rc 1/4
Power source 50/60Hz Single phase AC200V 17A
Weight Approx. 310 kg
Accessories
Shelf plate Punched stainless steel, 2 pcs

*The performance shown here is the value under the condition of the ambient temperature of 23deg.C±5deg.C, humidity of 65%RH±20%.

*The projection is not included for Internal dimensions and External dimensions.


Control panel
Produts
New Produts
Ovens
Laboratory Incubator
Products for Industry
Autoclave, Sterilizers
Plasma Cleaner, Asher
Freeze Dryer
Water Purifier
Rotary Evaporator
Water Circulator
Muffle Furnace
Water Bath
Spray Dryer
Laboratory Shaker
Laboratory Washer
Laboratory Stirrer
Laboratory Facilities
Vacuum Pump
For Biotechnology
X-Ray CT Scanner
Other Products
Product Brochure


Top
Privacy Policy
Copyright c 2012 YAMATO SCIENTIFIC CO., LTD. All rights reserved.