Product Code | Model | Exterior | Interior | Working surface | Glass door | Water faucet | Socket | Safety mechanism | Exhaust air volume | Internal static pressure | Adsorbent amount | Timer | Differential pressure | Lighting (LED) | Adsorption tower | External dimensions(W×D×H mm) | Power supply | Weight | Price |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A005627 | LFF-120L | Steel plate (powder coating) | Non-asbestos and non-combustible decorative board | Stainless Steel | Tempered glass 6mm thick, balance weight method | Single type x 1 pc | AC115/220V x 1 pc | Echaust delay timer, Door falling prevention stopper, Flow monitor | 12m3/min | 216Pa (22mm H2O) | 20kg Prefilter | 1 piece for totalizing adsorbent usage (0 to 9,999.9h) | 1 piece for pre-filter (0 to 490Pa/0 to 50mm H2O) | Type 32W x 1 pc | PVC | 1200×750×2600mm | AC115/220V Power Supply Phase: 115/220V Single Phase, 230/380V three phase |
330kg | - |
A005633 | LFF-120LU | Steel plate (powder coating) | Stainless Steel SUS304, 1mm thick (Baffle plate: Multi-slit type) | Stainless Steel | Tempered glass 6mm thick, balance weight method | Single type x 1 pc | AC115/220V x 1 pc | Echaust delay timer, Door falling prevention stopper, Flow monitor | 12m3/min | 216Pa (22mm H2O) | 20kg Prefilter | 1 piece for totalizing adsorbent usage (0 to 9,999.9h) | 1 piece for pre-filter (0 to 490Pa/0 to 50mm H2O) | Type 32W x 1 pc | Stainless Steel | 1200×750×2600mm | AC115/220V Power Supply Phase: 115/220V Single Phase, 230/380V three phase |
330kg | - |
A005624 | LFF-120S | Steel plate (powder coating) | Non-asbestos and non-combustible decorative board | Ceramic | Tempered glass 6mm thick, balance weight method | Single type x 1 pc | AC115/220V x 1 pc | Echaust delay timer, Door falling prevention stopper, Flow monitor | 12m3/min | 216Pa (22mm H2O) | 20kg Prefilter | 1 piece for totalizing adsorbent usage (0 to 9,999.9h) | 1 piece for pre-filter (0 to 490Pa/0 to 50mm H2O) | Type 32W x 1 pc | PVC | 1200×750×2600mm | AC115/220V Power Supply Phase: 115/220V Single Phase, 230/380V three phase |
330kg | - |
A005630 | LFF-120SU | Steel plate (powder coating) | Stainless Steel SUS304, 1mm thick (Baffle plate: Multi-slit type) | Ceramic | Tempered glass 6mm thick, balance weight method | Single type x 1 pc | AC115/220V x 1 pc | Echaust delay timer, Door falling prevention stopper, Flow monitor | 12m3/min | 216Pa (22mm H2O) | 20kg Prefilter | 1 piece for totalizing adsorbent usage (0 to 9,999.9h) | 1 piece for pre-filter (0 to 490Pa/0 to 50mm H2O) | Type 32W x 1 pc | Stainless Steel | 1200×750×2600mm | AC115/220V Power Supply Phase: 115/220V Single Phase, 230/380V three phase |
330kg | - |
A005628 | LFF-150L | Steel plate (powder coating) | Non-asbestos and non-combustible decorative board | Stainless Steel | Tempered glass 6mm thick, balance weight method | Single type x 1 pc | AC115/220V x 1 pc | Echaust delay timer, Door falling prevention stopper, Flow monitor | 16m3/min | 245Pa (25mm H2O) | 30kg Prefilter | 1 piece for totalizing adsorbent usage (0 to 9,999.9h) | 1 piece for pre-filter (0 to 490Pa/0 to 50mm H2O) | Type 32W x 1 pc | PVC | 1500×750×2600mm | AC115/220V Power Supply Phase: 115/220V Single Phase, 230/380V three phase |
390kg | - |
A005634 | LFF-150LU | Steel plate (powder coating) | Stainless Steel SUS304, 1mm thick (Baffle plate: Multi-slit type) | Stainless Steel | Tempered glass 6mm thick, balance weight method | Single type x 1 pc | AC115/220V x 1 pc | Echaust delay timer, Door falling prevention stopper, Flow monitor | 16m3/min | 245Pa (25mm H2O) | 30kg Prefilter | 1 piece for totalizing adsorbent usage (0 to 9,999.9h) | 1 piece for pre-filter (0 to 490Pa/0 to 50mm H2O) | Type 32W x 1 pc | Stainless Steel | 1500×750×2600mm | AC115/220V Power Supply Phase: 115/220V Single Phase, 230/380V three phase |
390kg | - |
A005625 | LFF-150S | Steel plate (powder coating) | Non-asbestos and non-combustible decorative board | Ceramic | Tempered glass 6mm thick, balance weight method | Single type x 1 pc | AC115/220V x 1 pc | Echaust delay timer, Door falling prevention stopper, Flow monitor | 16m3/min | 245Pa (25mm H2O) | 30kg Prefilter | 1 piece for totalizing adsorbent usage (0 to 9,999.9h) | 1 piece for pre-filter (0 to 490Pa/0 to 50mm H2O) | Type 32W x 1 pc | PVC | 1500×750×2600mm | AC115/220V Power Supply Phase: 115/220V Single Phase, 230/380V three phase |
390kg | - |
A005631 | LFF-150SU | Steel plate (powder coating) | Stainless Steel SUS304, 1mm thick (Baffle plate: Multi-slit type) | Ceramic | Tempered glass 6mm thick, balance weight method | Single type x 1 pc | AC115/220V x 1 pc | Echaust delay timer, Door falling prevention stopper, Flow monitor | 16m3/min | 245Pa (25mm H2O) | 30kg Prefilter | 1 piece for totalizing adsorbent usage (0 to 9,999.9h) | 1 piece for pre-filter (0 to 490Pa/0 to 50mm H2O) | Type 32W x 1 pc | Stainless Steel | 1500×750×2600mm | AC115/220V Power Supply Phase: 115/220V Single Phase, 230/380V three phase |
390kg | - |
A005629 | LFF-180L | Steel plate (powder coating) | Non-asbestos and non-combustible decorative board | Stainless Steel | Tempered glass 6mm thick, balance weight method | Single type x 1 pc | AC115/220V x 1 pc | Echaust delay timer, Door falling prevention stopper, Flow monitor | 19m3/min | 275Pa (28mm H2O) | 30kg Prefilter | 1 piece for totalizing adsorbent usage (0 to 9,999.9h) | 1 piece for pre-filter (0 to 490Pa/0 to 50mm H2O) | Type 40W x 1 pc | PVC | 1800×750×2600mm | AC115/220V Power Supply Phase: 115/220V Single Phase, 230/380V three phase |
430kg | - |
A005635 | LFF-180LU | Steel plate (powder coating) | Stainless Steel SUS304, 1mm thick (Baffle plate: Multi-slit type) | Stainless Steel | Tempered glass 6mm thick, balance weight method | Single type x 1 pc | AC115/220V x 1 pc | Echaust delay timer, Door falling prevention stopper, Flow monitor | 19m3/min | 275Pa (28mm H2O) | 30kg Prefilter | 1 piece for totalizing adsorbent usage (0 to 9,999.9h) | 1 piece for pre-filter (0 to 490Pa/0 to 50mm H2O) | Type 40W x 1 pc | Stainless Steel | 1800×750×2600mm | AC115/220V Power Supply Phase: 115/220V Single Phase, 230/380V three phase |
430kg | - |
A005626 | LFF-180S | Steel plate (powder coating) | Non-asbestos and non-combustible decorative board | Ceramic | Tempered glass 6mm thick, balance weight method | Single type x 1 pc | AC115/220V x 1 pc | Echaust delay timer, Door falling prevention stopper, Flow monitor | 19m3/min | 275Pa (28mm H2O) | 30kg Prefilter | 1 piece for totalizing adsorbent usage (0 to 9,999.9h) | 1 piece for pre-filter (0 to 490Pa/0 to 50mm H2O) | Type 40W x 1 pc | PVC | 1800×750×2600mm | AC115/220V Power Supply Phase: 115/220V Single Phase, 230/380V three phase |
430kg | - |
A005632 | LFF-180SU | Steel plate (powder coating) | Stainless Steel SUS304, 1mm thick (Baffle plate: Multi-slit type) | Ceramic | Tempered glass 6mm thick, balance weight method | Single type x 1 pc | AC115/220V x 1 pc | Echaust delay timer, Door falling prevention stopper, Flow monitor | 19m3/min | 275Pa (28mm H2O) | 30kg Prefilter | 1 piece for totalizing adsorbent usage (0 to 9,999.9h) | 1 piece for pre-filter (0 to 490Pa/0 to 50mm H2O) | Type 40W x 1 pc | Stainless Steel | 1800×750×2600mm | AC115/220V Power Supply Phase: 115/220V Single Phase, 230/380V three phase |